FIRE & SAFETY
Sources of Fire
The main source of fire in
any industry are electricity, smoking, friction, over heating material, hot
surfaces, burner flame ignition cutting ad welding, mechanical spark, static
spark and other sources asa exposure, the extent to which the industrial fire
is caused by this sources which has been shown as under:
Electricity
32%
Smoking
09%
Friction
10%
Hot surfaces 15%
Burner Flame 06%
Spontaneous Ignition 05%
Cutting and welding 09%
Mechanical Spark 02%
Static Spark 02%
Others 10%
Total 100%
Cause of Fire
1.
Cutting
& welding
2.
Heat/
over heat
3.
Elec.
Arc/Spark, Elec. Short circuit
4.
Metal
Spark
5.
Loco
Spark
6.
Mechanical
Fault
7.
Spontaneous
Combustion
8.
Static
Electricity
9.
Improper
Quenching
10.
Friction
11.
Open
Flame
12.
Not
Known
13.
Miscellaneous
and others
Important
fire haards in thermal power station
1.
Boiler
a) Accumulation of coal dust
b) Air pre hearts
c) Fuel oil
d) Rejected coal from coal
mills
2.
Turbine
a) Oil leakages from bearings
b) Oil leakages from Sealings
c) Oil leakages from Governing
system
d) Oil leakages from jacking
system Etc.
3.
Generator
a) Leakage of
b) Exciter sliperings
4.
Oil Facility
a) Fuel oil in tanks
b) Oil splashes mear oil
transfer pump & motors
c) Oil splashes in tunnels
5.
Coal handling plant
a) Spontaneous fire in coal
heaps
b) Coal dust
c) Conveyor belts
d) Mobable equipments
6.
Hydrogen plant
a) Electric Equipments
7.
Switch yard
a) Transformers
b) Breakers
c) CT/PT
8.
Transformers/Breakers/Cables
a) Generator transformers
b) Unit aux transformers
c) Switch gear rooms
d) Cable galleries
FIRE
PROTECTION
To reduce to loss of fire is FIRE PROTECTION.
Fire Protection is a planned approach to the provision
of adequate structural safe guard against the possibility of fire speard and
the availability of fixed and portable appliances which will readily available
in emergency.
The protection is done by various type of system.
FIRE
PROTECTION SYSTEM:-
System which are used to reduce the loss of fire is
FIRE PROTECTION system.
FIRE PROTECTION system.
There are two types of Fire Protection System
1. Active System.
2. Passive System.
ACTIVE
FIRE PROTECTION SYSTEM
As their name indicte that the systems which are
operated automatically in case of fire ate Active Fire Protection system
1. Sprinkler System
2. Mulsifyre System
3. CO2 injection System
4. Smoke Detection System
clubbed with total flooding system of any extinguishing agent.
5. Automatic Modulars.
6. fire resisting Coating for
H.T. Cables.
PASSIVE FIRE
PROTECTION SYSTEM
The systems which are operated manually in case of
fire to reduce fire loss are PASSIVE FIRE PROTECTION SYSTEM.
1. Smoke Detection System.
2. Heat Detectors.
3. Booster Pump System.
4. Landing Valves.
5. Hydrant System.
6. Dry Riser System.
7. Foam Pourers.
8. Hydrant Ring main
9. Deluge System.
10. First Aid Fire Fighting
Equipment.
11. Static Tank Water Spray
System.
Comments