Skip to main content

Summer Training Report For Thermal Power Plant- GENERATOR

GENERATOR

INTRODUCTION:-

          Alternators (A.C. generator) are also known as synchronous generator. Its main function is to convert mechanical power from a prime mover to electric power at a specific voltage and frequency.
Large generators are used to generate bulk power at thermal, hydroelectric and nuclear power stations.
3-phase synchronize generators are used in3-phase generation, transmission & distribution.

A)   STATOR:-
Stationary part, comes the armature winding in which voltage is generated i.e. output is taken from stator.
YOKE (frame): Cast iron for small machine and welded steel for large machine.
CORE: Assembled with high grade silicon content steel lamination to reduce iron losses.
STATOR WINDING: A 3-phase winding puts in the slot in stat connection.

B)   ROTOR:-
*Salient pole rotor                          *cylindrical rotor

Rotor is a rotating part, which produces the main field flux in which supply is given through d.c. generator calledencitor. in PTPS cylindrical rotor is used.
1.                Slots are at regular intervals & parallel to the shaft on which d.c. field winding occurs.
2.                Rotor is smoother machine, makes less winding losses & the operation is less noisy (due to uniform air gap).
3.                Cylinder rotor is two or four pole type alternator, which provides greater mechanical strength & permits more accurate balancing.
4.                It is driven by steam or gas turbine i.e. turbo generator or turbo.


D.C. EXCITER:-

          Excitation means production of flux by passing current in the field winding (rotor) from d.c. generator. As a rotor has no more residual magnetism, so first of all to make it electromagnetic i.e. dc is supplied to the rotor through brushes and slip ring.

PRINCIPLE-VOLTAGE GENERATION:-

          A prime mover (machine) supplies the mechanical energy input to the alternator i.e. steam cuts turbine or gas turbine. Actually, armature conductor on the stator, the field flux of the rotor & voltage is generated.

AVR (Automatic Voltage Regulator)
·        It controls the system voltage with alternator.
·       If any fault in the system to increase the excitation for maximum synchronizing.
·       Automatic Voltage regulation at the time of sudder cha of load/loss of load on the system.

Scheme Diagram:-

                             AVR                    Automatic voltage regulator
 



                             Exciter                 DC Generator
 



                             FB                        Field Breaker
 



                             SB                        Slip ring Brushes
 


          Field winding of Rotor                  Alternator

F) SYNCHRONISM CASE:-

1.                Frequency- supply frequency & grid frequency should be matched.
2.                Voltage- Generated voltage & System voltage should be matched.
3.                Phase sequence- Matching phase sequence (i.e. positive phase sequence) it should be at 60deg. either lagging or leading.
G) PROTECTION (ELECTRICAL):-
    I.        Negative phase sequence relay
    II.       Phase to phase fault.
III.             Phase to earth.
IV.            A) Over fluxing b) over current and c) over load d) over balanced load.
V.                Loss of excitation (Current power)
VI.            Anti-motoring (Failure of Prime Mover).
MOTORING
1.                Prime Mover
2.                    AVR
3.                    Generator

INDUCTION MOTOR:-
a)                Prime Mover (Turbine)- Fails  (trip)
b)                    Excitation- Zero (field breaker trips)
c)                     Generator Breaker- ON
Then the generator will act as Induction Motor. In case as motoring.

SUNCRONOUS MOTOR:-
a)      Prime Mover (Turbine) -      fails (trips)
b)      Excitation- Zero (field breaker trips)
c)      Generator Breaker- ON

Then the generator will act as Induction Motor. In case as motoring.

Comments

Popular posts from this blog

HIGH VOLTAGE TEST TECHNIQUES - Research Paper

Abstract: In this paper we have dealt with the high voltages testing techniques and High voltage measurement techniques.Different techniques like Chubb-Fortescue Method and Peak value measurement are also explained in detail. The method of measurement of voltage with the help of Sphere Gap and Construction of Sphere Gap and its Effects of earthed objects and atmospheric conditions on the accuracy of measurement are explained in details.Other techniques like Principle of measurement of voltage by Electrostatic Voltmeters and its Construction of Electrostatic Voltmetres help in study of High Voltages. Principle of Potential Dividers And types of potential dividers circuit are also covered in this paper. High test voltages generated in laboratories require special techniques for their measurement. Each type of high voltage namely; ac (), dc (=) and impulse () can be suitably measured with more than one different techniques. The choice of the method of measurement in a laboratory is ...