(i) Environmental Pollution

Environmental degradation connotes decrease in the quality of the environment due to human activities as well as natural effects volcanic eruptions, storms, landslides etc. Effects of environmental degradation are only local but local as well on the contrary, environmental degradation is not only local but global as well. On the contrary, environmental pollution is caused by human activities only.

(ii) Types of Pollution

(a) Air pollution caused by industries

Air pollution occurs in various industries where chimneys and other vents spew smoke, dust, gases like sulphur dioxide, carbon dioxide, nitric oxide, chlorine etc. Major sources of air pollution are brick kilns, cement plant, thermal power plants mining etc. the industrial units and refinery in and around Mathura is causing immense harm to the Taj Mahal, Bhartpur bird sanctuary and the like air pollution ,ay be classified as primary pollution and secondary pollutants. Primary pollution are those which originate from the sources of emission like chimneys and can comprise of carbon monoxide, sulphur dioxide, carbon dioxide, nitric oxide, dust funes etc. secondary pollutants are those which are generated when two or more primary pollutants react. Sulphur trioxide, ozone, peroxyacety1 nirtate (PAN)  etc. are examples of secondary pollutants. A concentration of 100 p.p.m. of carbon monoxide for an hour can cause death to human beings. Sulphur dioxide through sulphonation gats converted into sulphuric acid and can cause immense harm to paintings, buildings made of cellulose, marbal etc. leather becomes friable in due course of time under exposure to sulphur dioxide. Sulphur dioxide cause plant damage, broncho constriction in human and could be fatal when the gas is in high concentration and the exposure time is longer. Chlorine causes adverse effects on the whole repertory pollutants which ae photo chemically active help in the formation of smog. Air pollution can also be viewed in the light of
a)              Gaseous air pollutants and
b)             Particulate air pollutants.
Gaseous air pollutants in factories carbon dioxide carbon monoxide, chlorine in the second category of particulate air pollutant dust, ash, soot etc. Could be mentioned.


PREVENTION/CONTROL OF AIR POLLUTION

Air pollution due to particulate pollutants can be reasonably controlled by the following devices. Used in thermal power plants, iron and steel industries, paper industry efficiency of removal may even cross 99% with the added advantage of removal of particulate matters even lass than one micro metre in size. These may be fitted at the exit of the emitted tuners (as in chimneys other vents). Gravity settlers which have efficiency of lass than 50% are used for removing particles over 50 micrometers in size. These include spray towers, venture scrubbers and cyclonic scrubbers. In this category dynamic precipitators and cyclone collectors are included. Dynamic precipitators are more effective as compared to ordinary cyclone collectors. These filters are usually fitted in industrial unit where removal of very small dry particles even lass than one micrometre is desired. In this method the emitted furnace or gases are allowed exit through high rise chimney at a considerable height from the ground. Example a stack height of 40 meters may be adequate for certain industries whereby a large capacity thermal power plants can have a stack height of 275 metres. Air pollutants in particular can be put under check by proper arboriculture i.e. by intensive and planned plantation in the vicinity of industries. Plantation of trees like banyan, deodar, papal helps a lot in the control of dust menace as well as in the maintenance of a cleaner environment.














(b) WATER AND LAND POLLUTION (CAUSED BY INDUSTRIES) & THEIL CONTROL
Industries mainly responsible for generating industrial effluents and wastes could be distillery, tannery, sugar, plup and paper, oil refineries, dairy, chemicals and fertilizers, thermal power plant, iron and steel etc. industrial waste treatment should  aim at reducing an eco-friendly solution to the problem by proper recycling of the waste products. Industrial solid industrial pollutants pollute both if the treatment of industrial effluents or wastes is not proper it will have adverse effect on the health of humans, domestic animals, gricultural products the faune and flora will be in jeopardy.








Environmental Standards
 


Effluent
THERMAL POWER PLANT: STANDARDS FOR LIQUID EFFLUENTS
Source                                                   Parameter                                            Concentration not to exceed mg/I
                                                                                                                                (except for pH & Temp.)
Condenser Cooling Water (once pH                                                                6.5                 to                     8.5
through higher cooling system)         Temperature*                                      Not more than 50C than the higher
                                                                                                                                intake
Boiler Blowdown                                 Free                                       available 0.5
                                                                Chlorine                
                                                                Suspended                                solids 100
                                                                Oil           &                                 grease 20
                                                                Copper                                     (Total) 1.0
Cooling Tower Blowdown Free                                        available
                                                                Chlorine
                                                                Zinc                                                        1.0
                                                                Chromium                              (Total)  0.2
                                                                Phosphate                                             5.0
                                                                Other      corrosion                               inhibiting to be established on case by  
case basis by Central Board in case of Union Territories and State Boards in case of  States
As pond effluent                                  pH                                                          6.5                          to                        8.5
                                                                Suspended                               solids 100
                                                                Oil & grease                                          20

* Limit has been revised, please see new limit at Sr. No. 66C of the document
                                                                                                                                                Source: EPA Notification
                                                                                                                                (S.O. 844 (E)). Dt 19th Nov 1996)

Thermal Power Plant : Emission Standards

Generation capacity
Pollutant
Emission limit
Generation capacity 210 MW of more
Generation capacity las than 210 MW
Particulate malter
Particulate matter
150   mg/Nm3
300 mg/Ng 3

*Depending upon the requirement of local situation, such as protected area, the State Pollution Control Boards and other implementing agencies under the Environment (Protection) Act 1988, may prescribe a limit of 150 mg/Ng3 , irrespective of generation capacity of the plants.

Thermal Power Plants: Stack Height/Limits

Generation Capacity                                                                          Stack Height (Motors)
500 MW and above                                                                            275
200 MW/210 MW and above to lass than 500 MW                    220
Less than 200 MW/210 MW                                                            H= 14 Q 0.3 where Q is emission rate SO2 in

kg/hr, and H is Stack Height in metres. 

Comments

Popular posts from this blog

HIGH VOLTAGE TEST TECHNIQUES - Research Paper

Abstract: In this paper we have dealt with the high voltages testing techniques and High voltage measurement techniques.Different techniques like Chubb-Fortescue Method and Peak value measurement are also explained in detail. The method of measurement of voltage with the help of Sphere Gap and Construction of Sphere Gap and its Effects of earthed objects and atmospheric conditions on the accuracy of measurement are explained in details.Other techniques like Principle of measurement of voltage by Electrostatic Voltmeters and its Construction of Electrostatic Voltmetres help in study of High Voltages. Principle of Potential Dividers And types of potential dividers circuit are also covered in this paper. High test voltages generated in laboratories require special techniques for their measurement. Each type of high voltage namely; ac (), dc (=) and impulse () can be suitably measured with more than one different techniques. The choice of the method of measurement in a laboratory is ...